VARIOTEC® EGA

Ethane gas analysis device

  • Fast, clear differentiation between natural gas and biogenic swamp gas through ethane detection
  • Analysis of methane, ethane and propane in a single measurement
  • Highly sensitive semiconductor sensor for very low concentrations in the ppm range
  • Integrated gas chromatograph for precise component determination
  • Intuitive operation via jog dial, soft keys and task-oriented menu navigation
  • Internal data storage with USB interface for PC-supported documentation
  • Reduces the risk of costly excavation errors

The VARIOTEC® EGA is a portable, easy-to-use measuring device for ethane gas analysis that reliably and accurately determines the gas components methane, ethane and propane. It lets you differentiate between natural gas and biogenic swamp gas on-site, avoiding costly excavations and laboratory analyses. Thanks to a highly sensitive semiconductor sensor and an integrated gas chromatograph, it delivers dependable results even at very low concentrations in the ppm range — all within rugged ATEX explosion protection and simple, task-oriented operation.

Key Features

Gas component detection Measures methane (CH4), ethane (C2H6) and propane (C3H8) in one measurement.
Sensor technology Semiconductor sensor combined with an integrated gas chromatograph.
User interface Jog dial, three soft keys and task-oriented menu navigation.
Data management Internal storage with USB interface for digital documentation.
Explosion protection ATEX certified for use in potentially explosive atmospheres.

Specifications

Device

Dimensions (W x D x H)approx. 148 x 57 x 205 mm (5.83 x 2.24 x 8.07 in); 253 mm with supporting bracket
Weightapprox. 1000 g (35 oz), depending on equipment
DisplayMonochrome, 320 x 240 pixel
ControlsON/OFF key, 3 function keys, jog dial
InterfaceUSB
Protection ratingIP54

Methane sensor (thermal conductivity)

Measuring range0 - 100 % vol.
Resolution0.1 % vol. (0 - 9.9 % vol.); 1 % vol. (10 - 100 % vol.)
Response timet50 < 9 s, t90 < 17 s
Warm-up timeup to 90 s

Semiconductor sensor

Measuring range0 - 10,000 ppm
Resolution1 ppm (0 - 10); 2 ppm (10 - 100); 20 ppm (100 - 999)
Warm-up timeapprox. 1 min
Lifetime, expected5 years

Ethane analysis (gas chromatograph)

Measuring range0 - 12,000 ppm
Separating capacity25 ppm
Resolution1 ppm
Measurement time4 min
Lifetime, expected5 years

Operating conditions

Operating temperature-20 - 40 C (-4 - 104 F)
Humidity5 - 90 % r.h., non-condensing
Atmospheric pressure800 - 1100 hPa

Interested in the VARIOTEC® EGA?

Request pricing, availability, or a hands-on demo from our team.